    DMX-controlled breaker panel for architectural lighting in smaller venues.

    The LCLC is a compact, DMX-controlled load center that uses motorized breakers to provide a simplified, single-panel solution for architectural lighting control. It is designed for smaller venues like theaters, restaurants, and conference rooms requiring straightforward, reliable power management without complex on-site commissioning.

    Request a Quote

    Request A Quote

    Request more information about this product or speak directly with our sales team today.

    This field is for validation purposes and should be left unchanged.
    We route your message directly to the right team so you don’t get bounced around.


    The LC Series provides DMX512-addressable control for lighting circuits using motorized breakers within integrated panelboards and load centers. Engineered for lighting designers and integrators needing direct control over non-dimmed loads from a lighting console.

    A Smarter Alternative to Relay Panels

    Control

    DMX512

    Circuits

    Up to 41

    Voltage

    208Y/120V

    Emergency

    UL 924 Listed

    Form Factor

    Load Center
    DMX BREAKER PANEL

    Simplified DMX power control for architectural lighting.

    The LynTec LCLC series provides a streamlined, all-in-one solution for DMX-based lighting control by integrating motorized breakers directly into a compact load center. This design eliminates the need for separate relay panels and complex wiring, reducing both hardware costs and the wall space required for installation. It is an ideal choice for smaller performance venues, houses of worship, conference rooms, and restaurants where space and budget are primary considerations.

    Engineered for simplicity, the LCLC allows for individual or zoned circuit control using standard DMX512 commands, with addressing set via a simple on-board jumper system. Every panel includes a standard emergency auto-on feature for egress lighting (ETL listed to UL 924), ensuring code compliance without additional hardware.

    SYSTEM INTEGRATION

    Integrate the LCLC into your lighting system.

    The LCLC panel is designed to work with standard DMX-based lighting control and life safety systems.

    DMX512 Lighting Consoles

    Integrates with any lighting console, architectural controller, or show controller that outputs standard DMX512.

    Architectural Lighting Fixtures

    Provides switched power control for a wide range of lighting loads, including LED, incandescent, and fluorescent fixtures.

    Emergency and Life Safety Systems

    The standard UL 924 auto-on feature allows for simple integration with fire alarm or other emergency trigger systems.
    CONFIGURATION OPTIONS

    Configure your LCLC panel.

    LCLC panels are available in several configurations to match your project’s circuit count and power requirements.
    Panel Size Options

    Choose a panel size based on the total number of controlled circuits required for your lighting installation.

    • 26-Circuit Models: Ideal for smaller conference rooms, restaurants, or specific zones within a larger facility.
    • 41-Circuit Models: Provide higher circuit density for small theaters or venues with more complex lighting schemes.
    Main Breaker and Service

    Select the main service configuration based on your electrical design.

    • Main Breaker <100A: Standard configuration for lower-capacity services, available in both 26 and 41-circuit panels.
    • 150A, 200A, 225A Mains: Available for the 41-circuit panel to support higher load requirements.
    • Main Lugs Only (MLO): For applications where the panel is fed from an upstream breaker.
    Breaker Configurations

    Populate the panel with motorized breakers that match your specific circuit loads.

    • Amperage: Available in 15A, 20A, and 30A ratings.
    • Poles: Single, double, and three-pole breakers can be specified to control a variety of lighting loads.
    DMX Control

    The LCLC uses a straightforward DMX512 implementation for reliable control from any standard lighting console.

    • Jumper-Based Addressing: Set the starting DMX address with a simple jumper. Each subsequent breaker is assigned the next sequential address.
    • Individual or Zoned Control: Program breakers for individual control or group them in your lighting console for zone-based operation.
    LCLC MODELS

    Lighting Control Load Center Models

    LCLC panels are available in four configurations to fit a range of circuit count and main breaker requirements for smaller venues.
    Required

    LCLC Panel Models

    LCLC panels are a labor-saving one-panel alternative to DMX relay panels, ideal for smaller venues with limited wall space. They are available in 26 and 41 circuit sizes.
    WHY LYNTEC

    Intelligent Power Control, Simplified.

    • A single panel replaces a separate breaker panel and DMX relay system.
    • Simple jumper-based DMX addressing requires no programming or on-site commissioning.
    • ETL listed to UL 924 for emergency egress lighting, standard on every panel.
    • Energy-efficient design with no holding current for cool, long-term operation.
    FEATURES

    LCLC Load Center Features

    Engineered for simple installation, reliable operation, and built-in safety for architectural lighting applications.
    CAPABILITIES

    Features

    Standard DMX512 Control

    Control every circuit using standard DMX commands, with simple jumper-based addressing.

    Individual or Zoned Control

    Flexibly manage circuits one-by-one or group them into zones for simplified operation.

    Simplified Setup

    Designed for fast installation and intuitive operation without specialized training.

    No On-Site Commissioning

    Panels are ready for operation upon installation, saving time and project costs.

    UL 924 Egress Lighting

    An integrated emergency auto-on feature ensures egress lighting is activated when needed.

    Compact Footprint

    The single-panel design requires minimal wall space, ideal for tight locations.

    Reduced Hardware Costs

    Eliminates the need for separate DMX relay panels and associated wiring.

    Energy Efficient Operation

    Motorized breakers require no holding current, reducing power consumption and heat.
    01

    Save Space and Installation Costs

    An integrated load center with motorized breakers provides a one-panel solution, eliminating the cost and wall space of a separate DMX relay panel.
    • Combines breaker protection and DMX control
    • Reduces hardware and wiring complexity
    • Ideal for installations with limited wall space
    02

    Simple, Reliable DMX Control

    Control circuits individually or in zones using standard DMX512. Addressing is set with a simple jumper system, requiring no software or on-site commissioning.
    • Standard DMX512 protocol
    • Jumper-based addressing for fast setup
    • No factory start-up required
    03

    Code-Compliant Egress Lighting

    Every LCLC panel includes an emergency auto-on feature for egress lighting, ETL listed to UL 924, ensuring life safety compliance is built-in.
    • Standard on all LCLC panels
    • Automatically activates designated circuits
    • Simplifies meeting building safety codes
    SPECIFICATIONS

    LCLC Load Center Specifications

    Electrical, control, and compliance details for the LCLC family of DMX-controlled breaker panels.
    PANEL CONFIGURATIONS

    LCLC Panel Models

    All LCLC panels provide DMX-512 control for architectural lighting applications. Select the model that fits your project’s electrical specifications.

    Model Main Breaker / Lugs
    LCLC 326 For main breakers <100A
    LCLC 329 Main Lugs Only (MLO)
    LCLC 338 For main breakers <100A
    LCLC 341 150A, 200A, 225A, and MLO available

    Shared LCLC System Specifications

    Technical details common across the LCLC family. Refer to individual model data sheets for specific configurations.

    Electrical

    • Service
      3-Phase, 4-Wire, 208Y/120V
    • Circuit Capacity
      26 or 41 circuit models available
    • Main Breaker
      Up to 225A or Main Lugs Only (MLO)

    Control

    • Protocol
      DMX512
    • Addressing
      On-board jumpers
    • Breaker Control
      On, Off, or No Change per DMX command

    Compliance

    • Emergency Lighting
      ETL Listed to UL 924

    Common LCLC Specs

    • Control
      DMX-512
    • Emergency Feature
      Auto-on for egress lighting (ETL listed UL 924)
    • Energy Efficiency
      No holding current required

    Questions or Concerns?

    Let us know, we’re here to help! Contact Us

    PRODUCT SUPPORT

    LCLC Load Center Support

    Find documentation, guides, and answers to common questions for specifying and installing your LCLC panel.
    VIDEOS

    Setup & training video series.

    EPISODE 1 / 1 · 9:27
    Building a Controllable Breaker Panel Part Number
    DOCUMENTS

    Manuals, guides, and factsheets.

    FAQ

    FAQs about the LCLC

    Does the LCLC require a factory technician for setup?

    No, the LCLC is engineered for simple installation and does not require on-site commissioning or a factory start-up. The straightforward jumper-based DMX addressing allows electrical contractors to complete the setup without specialized training.

    How do I set the DMX address on an LCLC panel?

    DMX addressing is set using a simple physical jumper system on the control board inside the panel. No software, computer, or on-site commissioning is required. Once the starting address is set, each breaker is assigned the next sequential address.

    Is the LCLC suitable for large venues like arenas or auditoriums?

    The LCLC is designed for smaller circuit counts (up to 41) and is best suited for venues like small theaters, restaurants, and conference rooms. For larger facilities, a LynTec RPC or LCP series panelboard would be more appropriate.

    What emergency lighting features are included?

    Every LCLC panel comes standard with an emergency auto-on feature for egress lighting. This feature is ETL listed to the UL 924 standard, ensuring designated circuits will automatically activate to meet life safety codes.

    What is the difference between an LCLC and a separate relay panel?

    The LCLC integrates motorized circuit breakers and DMX control into a single load center. This eliminates the need for a separate DMX relay panel and the complex wiring between it and a standard breaker panel, saving space and installation labor.

    Ready to spec your next lighting project?

    Get a code-compliant configuration and submittal-ready drawings from a LynTec engineer. We help you simplify power infrastructure for any AVL installation.