Rack Power Distribution
Filter Products
Types
+Power Distribution
+Power Control
+Power Accessories
+Statuses
+Series
+Product Region
+Dependable power for any standard equipment rack.
LynTec rack power distribution units are built for simplicity and reliability. Designed to fit any standard 19-inch equipment rack, they offer a practical solution for powering everything from mobile carts to permanent installations. Each unit includes essential protection, with integrated spike suppression and AC line noise filtration to deliver cleaner power to sensitive electronics.
Installer-friendly features like rotated rear outlets to accommodate bulky power supplies and extra-long power cords simplify rack builds and reduce setup time. With a robust steel chassis and front-mounted circuit breakers, these PDUs are engineered for long-term, dependable service in any professional environment.
Engineered for the integrator.
Practical design that simplifies rack builds.
Essential protection for connected equipment.
Robust construction for commercial-grade reliability.
Your questions, answered.
Yes, we offer rack PDUs for both standard 15-amp and higher-capacity 20-amp circuits. The 15A models, like the JG11-15A, use a standard NEMA 5-15P plug that fits any common wall outlet.
The 20A models, such as the JG11.0-20A, are equipped with a NEMA 5-20P plug, which requires a corresponding 20A wall receptacle. It is important to match the PDU’s amperage rating to the circuit you intend to use for safe and reliable operation.
Yes, our power distribution units are engineered specifically for the demands of professional AV systems. They are built with robust components and appropriately rated circuit breakers to manage the high inrush currents typical of power amplifiers and digital signal processors during startup. This ensures reliable operation and helps prevent nuisance tripping that can occur with standard consumer-grade power strips.
Yes, our power conditioning and UPS products are engineered for professional AV installations. Most units feature standard 1U or 2U rack-mount form factors. We also include practical design elements, such as the rotated rear outlets on the JG 11-15A, which accommodate bulky wall-wart power supplies without blocking adjacent receptacles. Some models, like the SRA Series UPS, offer versatile mounting for rack, tower, or wall installations to fit any project requirement.
We offer a variety of standard cable and whip lengths that are suitable for most common rack builds and installations. These standard options help streamline ordering and ensure quick availability.
For projects with unique requirements or that need precise custom lengths to ensure a clean and efficient installation, please contact our sales and engineering team. We can work with you to specify a solution that meets your project’s exact needs.
Yes. The rear outlets on all RP Series power distribution units (PDUs) are specifically designed to accommodate bulky ‘wall wart’ style power adapters. The outlets are rotated 90 degrees and have generous spacing between them. This practical design prevents large adapters from blocking adjacent outlets, allowing you to use every available connection in your rack build.
No, this series of rack power distribution units is designed for straightforward, manual power control. They feature a master front-panel switch for turning most outlets on or off. They do not include onboard intelligence for network control or automated power sequencing.
For applications requiring controlled startup and shutdown sequences or remote IP-based control, we recommend exploring our Power Sequencing & Remote Control product families.
To properly size an SCV Series UPS, calculate the total power consumption (in watts) of all equipment you intend to protect. The SCV Series has a high 0.9 power factor, meaning its watt capacity is very close to its VA rating (e.g., a 1000VA model provides 900W).
Sum the wattage of your devices and select an SCV model like the SCV-10001 (900W), SCV-20001 (1800W), or SCV-30001 (2700W) that provides at least 20-25% overhead to accommodate inrush currents and future expansion.
For larger installations, you can network up to 10 NPAC units together over a standard IP network. When linked, they operate as a single, cohesive system. This allows you to manage and sequence up to 80 circuits from a single web interface, providing a scalable power control infrastructure that can grow from a single rack to a full facility.
Each PD Series unit is built to order. You can specify the exact number of circuits, receptacle types like NEMA 5-15/20R or locking L5-30R, and options such as isolated ground (IG). You also define the power feed, including the length of the wire harness, its exit location from the chassis, and whether it terminates in flexible metal conduit or a heavy-duty power cord. We can work from your design documents or our straightforward order menu to configure the perfect unit.
The rear AC outlets on our rack PDUs are rotated 90 degrees. This practical design allows you to plug in multiple oversized power adapters, often called ‘wall warts’, side-by-side without them physically blocking adjacent outlets. This simplifies rack wiring and ensures you can use all available connections, saving space and frustration during installation.
Our power distribution units are designed with practical features to make installations faster and cleaner. Rear outlets are rotated 90 degrees, allowing you to plug in bulky ‘wall wart’ power supplies without blocking adjacent outlets.
We also include extra-long 15-foot power cords on models like the JG 11-15A. This provides greater flexibility in rack placement and often eliminates the need for extension cords to reach distant wall receptacles, resulting in a safer and more professional installation.
A PD Series unit arrives on-site pre-assembled and pre-wired to your exact specifications. This eliminates the complex and time-consuming task of field-wiring individual outlets inside a rack, which significantly reduces on-site labor costs and minimizes the potential for wiring errors. With circuits and receptacles already labeled and the power harness cut to length, installation becomes a simple process of mounting the strip and connecting the power feed.
The integrated digital meter on the front panel provides at-a-glance visibility into your rack’s power consumption. A simple push-button allows you to toggle the display between showing the system’s input voltage (Volts) or the total current draw of connected equipment (Amps). This allows you to confidently monitor and manage your power loads in real time to prevent overloads.
The KIN 1000 is engineered with a compact 1U rack-mount chassis. This design is a significant advantage for integrators working with limited space in equipment closets or mobile AV racks. It allows for the addition of critical battery backup and power conditioning without sacrificing valuable rack real estate needed for other system components, simplifying rack layout and design.
Each PDU is equipped with a front-mounted, resettable circuit breaker rated for the unit’s maximum load (either 15A or 20A). In the event of an overload, the breaker will trip to protect all connected equipment.
Because the breaker is on the front panel, it can be reset quickly and easily without requiring access to the back of the rack, minimizing system downtime.
Our UPS systems are designed for the realities of professional installations. For maximum space efficiency, models like the KIN 1000 fit into a single (1U) rack space. For greater flexibility, the SRA Series can be installed in a 2U rack space, stood vertically as a tower, or mounted to a wall.
The SRA also features a rotating LCD panel that provides clear status information in any orientation, simplifying deployment in tight spaces.
The IP Series is designed to fit various system architectures. For standard equipment racks, we offer 1U rack-mount units like the iP-1515 and iP-1520. For high-density vertical power in a rack or cabinet, the iP PD1-4 provides multiple outlets in a compact strip. The iP-50 is a compact chassis model ideal for placement within furniture or behind displays.
Our rack PDUs come standard with an extra-long, 15-foot power cord. This length provides significant flexibility during installation, especially in mobile racks or in rooms where wall outlets are not located directly behind the equipment rack.
This feature often eliminates the need for extension cords, resulting in a cleaner, safer, and more reliable installation that saves time and reduces the number of potential failure points in your power chain.
The SQ-1500 has a total load capacity of 15 amps. This is sufficient to manage the startup sequence for typical equipment found in a single AV rack, such as audio amplifiers, digital signal processors, video switchers, and source devices.
Its 3-step sequence helps manage the inrush current from this equipment, preventing nuisance breaker trips and protecting sensitive electronics during power-up.
These rack PDUs provide essential protection for connected equipment. They feature an integrated Metal Oxide Varistor (MOV) for reliable spike and surge suppression against common voltage transients. Additionally, an onboard capacitor provides basic AC line noise filtration for cleaner power delivery.
This level of protection is ideal for general-use applications. For systems requiring more advanced protection or remote monitoring, consider our dedicated Power Conditioning & Surge Protection solutions.
A basic power distribution unit (PDU) is the ideal foundation for providing clean, protected power to a single rack where only manual on/off control is needed. They are a simple and reliable starting point for any installation.
Choose a networked power controller or sequencer when you need to manage system startup/shutdown order, control individual outlets remotely, or integrate power management with a third-party control system like Crestron, Q-SYS, or AMX.
Breakout cables are ideal for distributing power from a single multi-circuit source to multiple devices in a concentrated area, like an equipment rack or a lighting truss. Using one multi-pin cable run is significantly faster and cleaner than pulling several individual lines.
This approach simplifies cable management, reduces setup time, and minimizes potential connection errors, making it a more efficient and reliable solution for both permanent installations and portable rigs.
The JG Series is designed for standalone racks that need simple, reliable power distribution and basic protection. Specify a JG unit for applications like mobile AV carts, edit suites, or any single rack that does not require automated power sequencing, remote IP control, or integration with third-party control systems.
For systems that need scheduled operation, remote management, or controlled startup and shutdown sequences, consider our RPC, RPCR, or NPAC series panels.
The choice depends entirely on the installation environment. The flat-pack SL 350 and SLi-600 are specifically designed for decentralized, point-of-use applications where equipment is not located in a rack, such as behind a display or in a kiosk. The SLi-1000 is the ideal solution for centralized equipment in a standard 19-inch rack. Its 1RU design saves valuable rack space while providing higher capacity and optional network monitoring for critical AV and IT hardware.