Skip to main content
Closed Opens tomorrow 8 AM +1 913-529-2233
    SKU: SCV-20001 Market: North America Series: SCV
    SKU: SCV-20001 Market: North America Series: SCV

    SCV-20001 UPS Battery Backup

    2U rack-mount UPS with 2000VA on-line, double-conversion power protection.

    The SCV-20001 is a 2000VA uninterruptible power supply that provides true on-line, double-conversion protection for mission-critical electronics in a 2U rack-mount chassis. It is engineered for AVL racks that require complete isolation from power grid disturbances, ensuring stable voltage and reliable uptime for sensitive equipment.

    Request a Quote

    Request A Quote

    Request more information about this product or speak directly with our sales team today.

    This field is for validation purposes and should be left unchanged.
    We route your message directly to the right team so you don’t get bounced around.


    On-line, double-conversion Uninterruptible Power Supply (UPS) systems designed to provide the highest level of power protection for mission-critical AVL, broadcast, and IT equipment in rack-mount applications.

    Engineered for Uninterrupted Performance

    Capacity

    2000VA / 1800W

    Topology

    On-Line

    Form Factor

    2U Rack-Mount

    Full Load Runtime

    3 Minutes

    Warranty

    3-Year Electronics
    UPS BATTERY BACKUP

    Reliable power protection for mission-critical AVL systems.

    The SCV-20001 delivers dependable power protection for sensitive audio, video, and lighting systems. Its true on-line, double-conversion architecture completely isolates connected equipment from utility power, buffering it from sags, surges, and line noise that can damage electronics and disrupt operations. This design provides pure, stable sine-wave power and zero transfer time to battery, ensuring uninterrupted performance during power events.

    With a 2000VA, 1800-watt capacity, the SCV-20001 is sized for typical control room racks, edit suites, and small broadcast systems. The front-panel LCD provides at-a-glance status monitoring, while an optional SNMP card enables remote management, giving engineers greater visibility and control over their power infrastructure.

    COMPATIBLE ACCESSORIES

    Expand your SCV-20001 installation.

    Optional hardware and software that integrate directly with the SCV-20001 UPS.

    SCV-RAIL Rack Mount Kit

    Allows for secure, streamlined installation into any standard 19-inch equipment rack.

    SCV-SNMP Network Card

    Adds remote monitoring and management capabilities over an Ethernet network via web or SNMP.

    Sensitive AVL Electronics

    Ideal for protecting digital mixers, video switchers, servers, and control systems from power issues.

    Network Management Software

    Integrates with SentryHD software for comprehensive UPS monitoring, control, and automated shutdown.
    CONFIGURATION OPTIONS

    Configure your UPS installation.

    Select optional hardware to integrate the SCV-20001 into your specific environment.
    Mounting Options

    The SCV-20001 is designed for rack-mount or tower configurations.

    • Rack Mounting (Optional): An optional rack rail kit (Part Number SCV-RAIL) allows for secure installation in standard 19-inch equipment racks.
    • Tower Configuration (Standard): The unit can be used as a standalone tower without any additional hardware.
    Remote Management

    Add network visibility and control for remote administration.

    • SNMP Network Card (Optional): The SCV-SNMP card installs in the rear expansion slot to enable remote monitoring and management via an Ethernet network.
    WHY LYNTEC

    Dependable power infrastructure, built for AVL.

    • 3-year warranty on electronics, 1-year on batteries
    • On-line topology provides superior protection
    • Hot-swappable batteries for zero-downtime maintenance
    • US-based support for specification and installation
    FEATURES

    SCV-20001 UPS Features

    Core capabilities engineered for reliability and operational simplicity in professional AVL environments.
    CAPABILITIES

    Features

    2000VA / 1800W Capacity

    Provides reliable battery backup and power conditioning for demanding AVL equipment.

    On-Line Double Conversion

    Delivers the highest level of power protection by isolating equipment from raw utility power.

    0.9 Output Power Factor

    Offers more real power (watts) to protect modern electronics with high power factor loads.

    User-Friendly LCD Display

    Provides clear, real-time information on UPS status, load, and battery levels.

    Hot-Swappable Batteries

    Allows for battery replacement without powering down connected equipment for continuous uptime.

    2U Rack-Mount Design

    Fits standard 19-inch equipment racks for streamlined integration into AVL systems.

    Optional Network Management

    Add an SNMP card for remote monitoring, management, and automated shutdown capabilities.
    01

    True Double-Conversion Protection

    Completely isolates and regenerates power to protect sensitive equipment from all utility line disturbances, ensuring stable voltage and clean sine-wave output.
    • Zero transfer time to battery
    • Corrects for voltage sags and surges
    • Filters out electrical line noise
    02

    High-Efficiency Operation

    Advanced circuitry with a 0.9 output power factor converts more utility power into usable wattage, reducing energy waste and operational costs.
    • 0.9 power factor for modern loads
    • High-efficiency mode available
    • Reduces heat output in the rack
    03

    Clear System Visibility

    An intuitive front-panel LCD provides real-time status of load levels, battery health, and system alerts, simplifying diagnostics and management.
    • At-a-glance system monitoring
    • Audible and visual fault alarms
    • Optional SNMP card for remote management
    SPECIFICATIONS

    SCV-20001 UPS Specifications

    The complete technical data for integrating the SCV-20001 into your power infrastructure.

    SCV-20001 Technical Specifications

    Detailed electrical, physical, and battery specifications for the SCV-20001.

    Electrical

    • Power Capacity (VA)
      2,000
    • Power Capacity (Watts)
      1,800
    • Nominal Input Voltage
      120V
    • Output Voltage Regulation
      ± 1%
    • Topology
      On-Line, Double Conversion
    • Output Power Factor
      0.9

    Battery

    • Runtime at Full Load
      3 minutes
    • Runtime at Half Load
      10 minutes
    • Battery Type
      Maintenance-free sealed Lead-Acid
    • Hot-Swappable
      Yes

    Physical

    • Form Factor
      2U Rack-Mount / Tower
    • Weight
      47 lbs (21.3 kg)
    • Dimensions (W x H x D)
      17.2 x 3.5 x 16.1 in

    Communications & Management

    • Interface Port(s)
      USB, RS-232, SmartSlot
    • Control Panel
      Multi-function LCD status and control console
    • Optional Network Card
      SCV-SNMP

    Questions or Concerns?

    Let us know, we’re here to help! Contact Us

    PRODUCT SUPPORT

    SCV-20001 UPS Support

    Find user manuals, datasheets, and answers to common questions about the SCV-20001.
    FAQ

    FAQs about the SCV-20001

    Can I replace the batteries myself without shutting down?

    Yes, the SCV-20001 features hot-swappable batteries. You can safely replace the battery module while the UPS continues to power your connected equipment, ensuring zero downtime for maintenance.

    How much runtime can I expect from the batteries?

    The SCV-20001 provides approximately 3 minutes of runtime at a full 1800-watt load and 10 minutes at a half load of 900 watts. This is typically enough time for a safe, orderly shutdown of connected systems during an outage.

    What do I need to monitor this UPS remotely?

    To enable remote monitoring and management, you will need the optional SCV-SNMP network card. It installs in the rear SmartSlot and connects to your network, allowing you to manage the UPS via web browser or network management software.

    What is on-line, double-conversion and why does it matter?

    This UPS topology continuously converts incoming AC power to DC, then back to AC. This completely isolates your equipment from grid disturbances like sags, surges, and noise, providing the highest level of protection for sensitive electronics.

    Ready to protect your critical systems?

    Get a quote for your next installation and ensure your AVL equipment is protected by reliable, clean power from a trusted partner.