PD3B Custom Vertical Power Distribution
Custom vertical power distribution unit for up to (6) 20a or 30a circuits with (6) receptacles of choice.
The PD3B is a custom-configured vertical power distribution unit providing six receptacle positions for multi-circuit applications in equipment racks and enclosures. It is designed for integrators who need a specific layout of 20A or 30A receptacles in a compact, 29-inch chassis.
Request A Quote
Request more information about this product or speak directly with our sales team today.
Chassis Length
Receptacles
Circuit Rating
Configuration
Lead Time
Engineered to your exact power specifications.
The Juice Goose PD3B provides a robust platform for custom-built vertical power distribution, tailored to the unique requirements of your project. Built in a compact, 29-inch chassis, it features six available receptacle positions that can be populated with a mix of 20A duplex or 30A twist-lock connectors across multiple circuits. This build-to-order approach eliminates the need for off-the-shelf compromises, ensuring your power infrastructure precisely matches your system’s design.
Every PD3B is assembled in the US with short lead times, typically 3 to 5 business days for small quantities. This allows integrators to specify circuit orientation, wire harness length, and conduit type, resulting in a cleaner, faster, and more reliable installation.
Part of the trusted PD Series.
Integrate the PD3B into your rack.
Standard Equipment Racks
Custom Enclosures
Junction Boxes
Build your custom PD3B.
Define the power delivery for your rack. The six available positions can be configured with a mix of circuits and connector types.
- 20 Amp Circuits: Use standard NEMA 5/15-20R duplex receptacles for common equipment.
- 30 Amp Circuits: Use NEMA L5-30R twist-lock receptacles for high-current devices.
- Multiple Circuits: Combine different circuits in one chassis to power diverse loads from a single unit.
- Isolated Ground (IG): Specify IG receptacles for sensitive audio or video gear to reduce electrical noise.
Specify how the PD3B connects to your facility’s power source for a clean and compliant installation.
- Wire Harness Length: Order the precise length needed to reach the junction box, minimizing excess cable.
- Harness Exit Point: Choose a top or bottom exit from the chassis to match your cable pathways.
- Conduit or Cord: Select flexible metal conduit for permanent installs or a heavy-duty SJT power cord.
The PD3B is designed for flexible mounting in a variety of racks and enclosures.
- Adjustable Brackets: Reposition the side mounting brackets along the chassis to align with your rack rails.
- Vertical Mounting: The 29-inch length is ideal for mid-size racks or for targeted power distribution.
- Shallow Depth: At only 2.125 inches deep, it installs easily behind equipment without obstructing access.
Custom power infrastructure, simplified.
-
Built to your exact specifications
-
Shorter lead times for custom PDUs
-
Reduces installation complexity and labor
-
Durable steel chassis, made in America
Complete your power-control system
PD3B Features
Features
Six Receptacle Positions
Multiple Circuit Design
Custom Wire Harness
Labeled Circuits
Shallow Chassis
Adjustable Mounting
Flexible Conduit Option
Isolated Ground Available
Built to Your Specifications
- Mix of 20A and 30A circuits
- NEMA 5/15-20R or L5-30R receptacles
- Isolated ground options available
- Top or bottom wire harness exit
Fast, Dependable Delivery
- 3 to 5 business day lead time
- For orders of six pieces or less
- Assembled in the USA
- Reduces project delays
Designed for the Integrator
- Shallow 2.125-inch chassis depth
- Adjustable side mounting bracket
- Clearly labeled circuits and wires
- Fits behind rack-mounted equipment
PD3B Specifications
PD3B Technical Specifications
Chassis
-
Length29.0 inches
-
Width2.6 inches
-
Depth2.125 inches
-
MaterialSteel
-
FinishBlack Powder Coat
Electrical Capacity
-
Receptacle Positions6
-
Maximum Amperage30A per circuit
-
Available ReceptaclesNEMA 5/15-20R, NEMA L5-30R
-
GroundingStandard or Isolated Ground (IG)
Configuration
-
Wire Harness ExitTop or Bottom
-
Power CordSJT cord or flexible metal conduit
-
Lead Time3-5 business days (orders of 6 or less)
Questions or Concerns?
Let us know, we’re here to help! Contact Us
PD3B Support
Manuals, guides, and factsheets.
FAQs about the PD3B
Yes. The six receptacle positions can be configured with a mix of 20A duplex and 30A twist-lock receptacles, connected to the appropriate number of circuits as specified for your project.
Contact a LynTec or Juice Goose representative with your requirements. We will help you specify the circuits, receptacles, and harness details to generate a quote for your specific build.
You can specify the length of the wire harness, whether it exits the top or bottom of the chassis, and if it is enclosed in flexible metal conduit or a standard SJT power cord.
For orders of six units or less, the standard lead time is 3 to 5 business days. Contact us for lead times on larger quantities.
Ready to spec your custom power strip?
Provide our team with your circuit, receptacle, and harness requirements. We will deliver a quote and drawing for your submittal package, typically within one business day.