LA Series Audio Line Surge Protector
Surge protection modules for outdoor speaker lines with multiple clamping voltages.
The LA Series provides three-stage surge protection for audio signal lines, guarding outdoor speaker installations against lightning-induced currents and catastrophic equipment damage. It is designed for performance venues and outdoor facilities needing reliable, inexpensive protection for speaker systems exposed to the elements and electrical surges.
Request A Quote
Request more information about this product or speak directly with our sales team today.
Application
Protection
Max Surge
Response Time
Mounting
Protect outdoor audio equipment from lightning-induced surges.
Equipment installed outdoors, like speakers in stadiums or on light poles, provides an attractive path for lightning. A nearby strike can induce high current and cause catastrophic damage to connected audio equipment. The LA Series provides simple and inexpensive protection, diverting surges up to 5,000 amps in under a nanosecond.
Its hybrid, three-stage design combines fast-acting MOVs, inductors, and silicon avalanche diodes for robust protection. The modular design, which mates with a required PCB-1B base, allows for easy replacement of the protection module after a significant lightning event, simplifying long-term maintenance.
Part of the trusted L Series.
Complete your LA Series installation.
PCB-1B Mounting Base
Outdoor Speaker Systems
70-Volt Audio Systems
Spec your protection.
Choosing the correct LA model is critical for effective protection without impacting audio performance.
- Clamping Voltage: Models are available with clamping levels from 15V to 150V.
- Application Matching: The appropriate model is a function of the speaker’s impedance and wattage. For example, the LA 100 is designed for 70-volt speaker systems.
- Guidance: Contact a LynTec engineer with your speaker specifications to determine the correct model for your project.
The LA Series uses a two-part system for easy installation and serviceability.
- PCB-1B Base (Required): The protection module is not a standalone unit. It must be installed onto the PCB-1B mounting base, which is priced and sold separately.
- Modular Connection: The LA module’s gold-plated circuit card securely mates with the base, allowing for quick and easy replacement when needed.
The module can be configured for standard or higher-current speaker lines.
- Standard (5A): By default, the LA module protects two separate pairs of audio lines, each up to 5 amps.
- High-Current (10A): For loads up to 10 amps, the terminals can be bridged, restricting the module to protecting a single pair of leads.
Reliable protection, simplified.
-
Specialized three-stage protection for audio signal lines
-
Engineered for outdoor and exposed installations
-
Modular design simplifies long-term service and replacement
-
Decades of experience in power and signal protection
Complete your power-control system
LA Series Features
Features
Three-Stage Hybrid Circuitry
5,000 Amp Surge Capacity
Nanosecond Response Time
Low Impedance Design
Dual Pair Protection
High Current Option
Modular Installation
Three-Stage Hybrid Protection
-
Combines MOVs, inductors, and silicon avalanche diodes (SAD)
-
Diverts surges up to 5,000 amps
-
Responds in under one nanosecond to protect sensitive equipment
Modular and Serviceable
-
Gold plated circuit card mates with PCB-1B base
-
Allows for simple periodic replacement
-
Enables quick recovery after a major surge event
Flexible Application
-
Protects two pairs of audio lines up to 5 amps each
-
Terminals can be bridged for a single 10-amp line
-
Multiple models with different clamping voltages are available
LA Series Specifications
LA Series Specifications
Protection
-
Circuit DesignHybrid, Three-Stage (MOV, Inductor, SAD)
-
Maximum Surge Current5,000 Amps
-
Response Time< 1 nanosecond
-
Clamping Voltage15V to 150V (model dependent)
-
Impedance0.02 ohms
Electrical
-
Line CapacityTwo pairs of audio lines
-
Maximum Current (per pair)5 Amps
-
Maximum Current (bridged)10 Amps (single pair)
Physical
-
ConnectionGold plated circuit card
-
Required MountingPCB-1B Mounting Base (sold separately)
Questions or Concerns?
Let us know, we’re here to help! Contact Us
LA Series Support
FAQs about the LA Series
Yes. Each module can protect two pairs of lines up to 5 amps each. For higher current loads up to 10 amps, the terminals can be bridged to protect a single pair of lines.
The correct model depends on your speaker’s wattage and impedance, which determines the required clamping voltage. For example, the LA 100 model is for 70-volt systems. Contact a LynTec engineer with your speaker specs for a precise recommendation.
The module is designed to be easily replaceable. We recommend periodic inspection and replacement as part of a regular maintenance schedule, or immediate replacement following a known significant lightning event in the vicinity of the installation.
No. The LA module requires the PCB-1B mounting base for installation. The base is priced and sold separately.
It’s a robust circuit design that uses three types of components in sequence: Metal Oxide Varistors (MOVs), inductors, and Silicon Avalanche Diodes (SADs). This provides more comprehensive protection against a wider range of electrical surges than a single-stage design.
Need help selecting the right model?
Our team can help you match the correct LA Series protector to your speaker system’s specifications. Contact us for guidance and availability information.