Skip to main content
Closed Opens at 8 AM +1 913-529-2233
    SKU: SCLC Region: North America
    SKU: SCLC Region: North America

    SCLC Series Load Center Panels

    RS-232 controlled load center panels with motorized breakers for simplified power control.

    The SCLC series is a family of RS-232 controlled load center panels using motorized breakers to provide a compact, single-panel alternative to traditional relay systems. It is designed for smaller installations or areas with limited wall space, simplifying deployment for integrators who need reliable, serially-addressable circuit control.

    Request a Quote

    Request A Quote

    Request more information about this product or speak directly with our sales team today.

    This field is for validation purposes and should be left unchanged.
    We route your message directly to the right team so you don’t get bounced around.



    A Smarter Alternative to Relay Panels

    Control

    RS-232 Serial

    Circuits

    Up to 41

    Voltage

    208Y/120V

    Panel Type

    Load Center

    Breakers

    Motorized
    SCLC SYSTEM OVERVIEW

    Simplified serial control for every circuit.

    The LynTec SCLC Series provides a streamlined, single-panel solution for circuit breaker control, replacing the complexity and cost of separate relay panels. By integrating motorized circuit breakers directly into a compact load center, the SCLC saves significant wall space and reduces installation labor. Each breaker is individually addressable over a standard RS-232 serial connection, making it simple to integrate with building management or third-party control systems.

    Engineered for efficiency and reliability, SCLC panels require no holding current to maintain their state, ensuring cool operation and a long service life. With standard features like automatic load shedding and brownout protection, the SCLC delivers intelligent power control in an economical, easy-to-commission package.

    SYSTEM INTEGRATION

    Integrate the SCLC with your facility controls.

    The SCLC series is designed to work with standard serial control systems and electrical infrastructure.

    Building Management Systems

    Integrates directly with any BMS that can output RS-232 serial commands for lighting and power control.

    Third-Party AV Control Systems

    Connects to AV controllers from manufacturers like Crestron, AMX, and Extron via their serial ports.

    IP-to-Serial Converters

    Pair with a third-party IP-to-Serial device to enable control over a standard TCP/IP network.
    CONFIGURATION OPTIONS

    Configure your SCLC panel.

    Select the panel size and model that matches your project’s electrical service and circuit count.
    Available Models

    SCLC panels are available in multiple configurations based on the main breaker rating or Main Lug Only (MLO) requirements.

    • Standard Models (less than 100A): Models like the SCLC 127, SCLC 326, and SCLC 338 are designed for systems with main breakers rated under 100A.
    • High-Amperage Models (greater than 100A): The SCLC 129 and SCLC 341 accommodate main breakers from 150A to 225A for higher capacity installations.
    • Main Lug Only (MLO) Models: MLO variants, including the SCLC 329, are available for applications where a main breaker is not required in the panel.
    Panel Size Options

    Choose between two primary panel sizes to match the total number of controlled circuits required for your installation.

    • 26-Circuit Panels: Ideal for smaller projects or distributed power control applications with fewer circuits to manage.
    • 41-Circuit Panels: Provides higher circuit density for more centralized control applications or larger venues.
    Control and Integration

    The SCLC series is built around a simple and robust serial control architecture for easy integration.

    • RS-232 Control: The native control protocol, allowing direct integration with building management systems and third-party serial controllers.
    • Simple Addressing: An onboard jumper system sets the starting address for all breakers, simplifying commissioning.
    • IP Integration: Can be connected to modern IP networks using a standard third-party IP-to-Serial converter.
    Built-in Protection

    Every SCLC panel includes a suite of standard features to protect connected equipment and ensure reliable operation.

    • Automatic Load Shedding: Helps manage power consumption by automatically turning off non-essential circuits.
    • Brownout Shutdown: Protects sensitive electronics by shutting circuits down during under-voltage conditions.
    • Emergency Override: Provides a standard, accessible method for manual override in critical situations.
    SCLC MODELS

    Choose the Right SCLC Panel for Your Application

    SCLC panels are available in multiple configurations to match your specific voltage, phase, and main breaker requirements.
    Required

    Serial Controlled Load Center Panels

    Select the appropriate SCLC panel based on your main breaker size, phase, and circuit count requirements.
    WHY LYNTEC

    A simpler, more reliable alternative to relay panels.

    • Saves wall space by combining distribution and control
    • Reduces installation and hardware costs
    • Energy-efficient design with no holding current runs cool
    • Simple jumper-based setup for fast commissioning
    FEATURES

    SCLC Series Features

    An overview of the standard capabilities engineered into every SCLC load center panel.
    CAPABILITIES

    Features

    Motorized Circuit Breakers

    Provides reliable, remote on/off control for each circuit without external relays.

    Simple RS-232 Addressing

    An onboard jumper system allows for fast and easy setup of serial addresses.

    Energy-Efficient Operation

    Requires no holding current to maintain breaker state, reducing heat and energy use.

    Automatic Load Shedding

    A standard feature that helps manage power consumption during peak demand.

    Brownout Protection

    Automatically shuts down circuits during under-voltage events to protect connected equipment.

    Emergency Override

    Enables immediate manual control for life safety and emergency egress situations.

    Flexible Circuit Control

    Allows for individual or grouped zone control of circuits via serial commands.

    Easy Commissioning

    Engineered for simple setup without requiring a factory technician for start-up.
    01

    Save Space and Reduce Costs

    Combining motorized breakers and control logic in a single load center eliminates the need for separate relay panels, saving wall space and hardware costs.
    • Single panel for distribution and control
    • Reduced installation and wiring labor
    • Compact footprint for tight locations
    02

    Efficient and Reliable by Design

    Motorized breakers require no holding current or heat sinks to maintain their state. This energy-efficient design runs cool, increasing component longevity.
    • Zero holding current for on or off states
    • Lower operational energy costs
    • Designed for long-term reliability
    03

    Simplified Setup and Integration

    A simple jumper system makes setting RS-232 addresses straightforward, with no on-site commissioning or factory start-up required for basic operation.
    • Easy jumper-based addressing
    • Integrates with building management systems
    • Individual or zone control of circuits
    SPECIFICATIONS

    SCLC Series Specifications

    System-level electrical, control, and mechanical details for the SCLC family of products.
    SCLC PANELS

    Serial Controlled Load Center Panels

    Select the appropriate SCLC panel based on your main breaker size, phase, and circuit count requirements.

    Model Phase Circuits Main
    SCLC 127 3-Phase 26 For main breakers <100A
    SCLC 129 3-Phase 26 For main breakers >100A and MLO
    SCLC 326 3-Phase 26 For main breakers <100A
    SCLC 329 3-Phase 26 Main Lugs Only (MLO)
    SCLC 338 3-Phase 41 For main breakers <100A
    SCLC 341 3-Phase 41 150A, 200A, 225A, MLO available

    Shared SCLC System Specifications

    Technical details common across the SCLC series. Individual model specifications are available on their respective data sheets.

    Electrical

    • Service
      3-Phase, 4-Wire, 208Y/120 VAC
    • Circuit Capacity
      26 or 41 circuits
    • Breaker Types
      Motorized; 1, 2, or 3-pole
    • Breaker Ratings
      15A, 20A, 30A

    Control

    • Primary Protocol
      RS-232 Serial
    • Addressing
      Onboard jumpers for setting start address
    • Commands
      On, Off, No Change per circuit

    Mechanical

    • Panel Type
      Load Center
    • Mounting
      Surface or flush mount (trim kit required)

    Common SCLC Panel Specs

    • Control
      RS-232
    • Breaker Type
      Motorized
    • Voltage
      208Y/120V, 3-Phase, 4-Wire
    • Load Shedding
      Standard
    • Brownout Protection
      Standard
    • Emergency Override
      Standard

    Questions or Concerns?

    Let us know, we’re here to help! Contact Us

    PRODUCT SUPPORT

    SCLC Series Support

    Find documentation, application notes, and answers to common questions for the SCLC series.
    FAQ

    FAQs about the SCLC Series

    Can I control an SCLC panel from an IP-based system?

    Yes. While the SCLC’s native control protocol is RS-232, it can be easily integrated into a modern IP network using a standard, third-party IP-to-Serial converter. This allows control from network-based building management or AV control systems.

    How do I address the breakers for RS-232 control?

    The SCLC uses a simple jumper system on the control board. You set the starting address with the jumper, and each subsequent motorized breaker is assigned the next sequential address automatically. This makes setup quick and straightforward without complex software.

    How is an SCLC panel different from a traditional relay panel?

    The SCLC integrates motorized breakers directly into a load center, combining power distribution and circuit control into one unit. This saves space, reduces hardware costs, and simplifies wiring compared to installing a separate breaker panel and relay panel.

    What does the brownout protection feature do?

    The standard brownout feature automatically turns off controlled circuits when an under-voltage condition is detected. This helps protect sensitive connected equipment from potential damage caused by unstable power, then allows for a controlled restart once stable power returns.

    Which SCLC model is right for my project?

    Model selection depends on your main electrical service and circuit count. Choose a model based on the main breaker amperage (e.g., under 100A, over 100A, or Main Lug Only) and the required number of circuits (26 or 41). Contact a LynTec engineer for help with configuration.

    Ready to spec your next install?

    Get submittal-ready drawings and a code-compliant configuration from a LynTec engineer. We can help you select the right SCLC panel for your specific application.