Skip to main content
Closed Opens at 8 AM +1 913-529-2233
    SKU: RC5-RM Region: North America Series: RC
    SKU: RC5-RM Region: North America Series: RC

    RC5 Remote Control

    Remote control and status monitor for CQ Series power sequencers.

    The RC5 is a remote control accessory that provides secure, manual sequence-up, sequence-down, and pause control for any connected CQ Series sequencer unit. It is designed for installations requiring a simple, reliable remote trigger point, with options for rack or wall mounting to fit any control room.

    Request a Quote

    Request A Quote

    Request more information about this product or speak directly with our sales team today.

    This field is for validation purposes and should be left unchanged.
    We route your message directly to the right team so you don’t get bounced around.


    A family of remote control accessories for the LynTec CQ Series power sequencing ecosystem. RC Series products provide simple, hard-wired control and status monitoring from convenient wall-mount or rack-mount locations.

    Extend Control and Visibility

    Compatibility

    CQ Series

    Control

    Up, Down, Pause

    Connection

    RJ-45

    Power Source

    From CQ Unit

    Mounting

    Rack
    CQ SERIES ACCESSORY

    Simple, reliable remote sequencing control.

    Extend control of your CQ Series power sequencing system to a secure, convenient location. The RC5 provides a dedicated remote trigger and a clear, at-a-glance status monitor for your entire power-up or power-down sequence. Installation is simplified with an 8-wire cable with RJ-45 connector that provides both control signal and operating power directly from the host CQ unit, eliminating the need for a separate power supply or complex wiring.

    The rack-mount RC5 is available with keyswitch, rotary switch, or keypad interfaces, allowing integrators to specify the exact control type required for any venue, from a secure equipment room to a public-facing control panel.

    COMPATIBLE ACCESSORIES

    Designed for the CQ Series Ecosystem.

    The RC5 integrates seamlessly with LynTec CQ Series sequencers and accessories.

    LynTec CQ Series Sequencers

    Provides a dedicated remote trigger and status point for any CQ Series power sequencer.

    RCDM3 Remote Control Combiner

    Integrates with the RCDM3 to allow up to three RC5 units to control a single CQ sequencer or system.
    CONFIGURATION OPTIONS

    Choose your control interface.

    Select the mounting style and control type that best fits your installation’s security and operational needs.
    Mounting Options

    The RC5 is available in two form factors to match your installation environment:

    • Rack Mount (RM): Fits in a standard 19-inch equipment rack for centralized control.
    • Wall Mount (WM): Mounts in a standard gang box for convenient access in performance spaces or control booths.
    Control Types

    Choose the control interface that matches your facility’s security requirements:

    • Keyswitch (RC5-RM, RC5-WM): Provides security by preventing unauthorized operation of the power sequence.
    • Rotary Switch (RC5RM-RS, RC5WM-RS): Offers simple, convenient sequence control when physical security is not a primary concern.
    • Keypad (RC5-KPS): A wall-mounted option that requires a code for operation, combining security with keyless access.
    WHY LYNTEC

    Extend your power control with confidence.

    • Simple, reliable control for the proven CQ Series
    • Plug-and-play installation with an 8-wire cable with RJ-45 connector
    • No external power supply needed, reducing complexity
    • Built for long-term use in commercial AVL environments
    FEATURES

    RC5 Remote Control Features

    Engineered for simple, reliable remote operation of CQ Series power sequencers.
    CAPABILITIES

    Features

    Full Sequence Control

    Provides dedicated controls for Sequence Up, Sequence Down, and Pause functions.

    Clear LED Status Indicators

    At-a-glance feedback on sequence operation, completion, and overall system status.

    Multiple Control Options

    Available with a keyswitch for security, a rotary switch, or a push-button keypad.

    Flexible Mounting

    Choose between standard 19-inch rack mount or wall mount form factors.

    Simple RJ-45 Connection

    Connects to any CQ sequencer with a single, standard network patch cable.

    No External Power Required

    Draws operating power directly from the connected CQ unit, simplifying installation.
    01

    Plug-and-Play Installation

    A single, standard RJ-45 cable connects the RC5 to a CQ sequencer, providing both control and power. This simplifies deployment and reduces installation labor.
    • Standard RJ-45 connection
    • No external power supply required
    • Reduces wiring complexity and points of failure
    02

    Control Matched to Your Needs

    Choose the interface that fits your venue’s operational and security requirements, from a simple rotary switch to a secure keyswitch or keypad.
    • Keyswitch models for secure, authorized access
    • Rotary switch models for convenient operation
    • Wall and rack mount versions for flexible placement
    03

    At-a-Glance System Status

    Integrated LED indicators provide immediate visual feedback on the state of your power system, simplifying operation and troubleshooting.
    • Indicator for sequence in operation
    • Indicator for sequence completion
    • Indicator for overall system status
    SPECIFICATIONS

    RC5 Remote Control Specifications

    All physical and operational specs in one place.

    RC5 Remote Control Specifications

    Technical details for integrating RC5 remote controls with your CQ Series power sequencing system.

    Control and Indicators

    • Functions
      Sequence Up, Sequence Down, Pause
    • Indicators
      LED for Sequence Operation, Completion, System Status

    Physical and Electrical

    • Connection Type
      RJ-45
    • Power Source
      Supplied by connected CQ Series unit
    • Mounting Options
      19-inch Rack Mount (RM), Wall Mount (WM)

    Questions or Concerns?

    Let us know, we’re here to help! Contact Us

    PRODUCT SUPPORT

    RC5 Remote Control Support

    Documentation and answers to common questions.
    FAQ

    FAQs about the RC5 Remote Control

    Can I use multiple RC5 controllers on one CQ system?

    Yes, you can control a single CQ sequencer or system from up to three different locations by using the RCDM3 Remote Control Combiner accessory. This allows for flexible control point placement.

    Does the RC5 need its own power outlet?

    No, the RC5 does not require an external power supply or separate power outlet. It draws all necessary operating power directly from the CQ Series unit it is connected to via the RJ-45 cable.

    How does the RC5 connect to a CQ sequencer?

    The RC5 connects to any CQ Series sequencer using a single, standard RJ-45 network patch cable. This one cable handles both the control signals and provides power to the RC5 unit.

    Is there a wall-mounted version of the RC5?

    Yes. The RC5 is available in both rack mount (RM) and wall mount (WM) versions to fit different installation requirements. The wall mount versions are designed to fit in a standard gang box.

    What is the difference between the keyswitch and rotary switch models?

    The keyswitch models (RC5-RM, RC5-WM) are designed for security, requiring a key to operate the power sequence. The rotary switch models (RC5RM-RS, RC5WM-RS) offer convenient, unrestricted access for operation.

    Ready to spec your next install?

    Get submittal-ready drawings and a code-compliant configuration from a LynTec engineer.